How to use and validate iHP Cycles

How to use and validate iHP Cycles


Ionized Hydrogen Peroxide (iHP)


iHP is hydrogen peroxide which is split into reactive oxygen species (ROS) by Binary Ionization Technology (BIT) that increases the efficacy and effectiveness of its use as a disinfectant. iHP is also classified as a sterilant, meaning that it can achieve sterilization of a surface, material, or room. As a sterilant it can eradicate all types of microorganisms as defined by the hierarchy of disinfection.


iHP is advantageous in part due to its ease of use and favorable safety profile. iHP degrades into nontoxic by-products by recombining into water and oxygen molecules which can be easily and safely exhausted back into the environment. No special filters or scrubbers are needed, unlike other gaseous disinfectants that are in use. Additionally, iHP has great material compatibility, meaning that it is gentle on equipment and construction materials while still being effective at reducing bioburden.


Using iHP


iHP is generated using a specialized generator that ejects a stream of specially formulated hydrogen peroxide through a high voltage plasma arc. It is this action which splits the H2O2 molecule into ROS such as hydroxyl radicals. Coupled with the small particle sizes that are generated plus the high velocity that is achieved, iHP can penetrate the smallest openings within the space. As an oxidizing agent iHP eradicates microorganisms by lysing them.


iHP generators can be portable or integratable and application of iHP can be in the form of whole space fogging or direct surface spraying. With whole room fogging, applicator heads are set up on tripods and arranged in a formation which allows the iHP to move around the room. With direct surface spraying, the applicator heads are switched to handheld mode and surfaces within a room, or of materials, are directly sprayed with iHP.


iHP Biodecontamination Cycle Development and Validation


Developing and validating your iHP biodecontamination (biodecon) cycle is an important part in using iHP in your cleanroom or facility. When developing your biodecon cycle you must take into consideration your room size and layout, and the level of disinfection you want to achieve. A biodecon cycle has three phases: Injection phase, Dwell phase, and Aeration phase. Depending on your room size, equipment layout, and air changes per hour these three times can vary from room to room and facility to facility:


Injection phase: During the Injection phase, iHP is injected into the space. Adequate time is required for the whole calculated dose to be injected into the room.


Dwell phase: During the Dwell phase the iHP circulates and eradicates any microorganisms it encounters. Enough time must be allowed for the iHP to circulate and work effectively.


Aeration phase: During the Aeration phase the iHP is diluted with circulating air and is removed from the room. In parallel the ROS recombine to create water and oxygen. During this phase, the H2O2 ppm must drop below 1ppm to be deemed safe for entry again.


When developing these phases there are tools you can use to help.


1. H2O2 monitor: This device monitors your H2O2 levels and indicates when the desired H2O2 dose is reached and how long it is sustained for. In addition, a H2O2 monitor is used to measure how long the aeration phase needs to be set for.


2. Chemical indicators (CIs): CIs are placed around the space being deconned and indicate, via color change, whether H2O2 is reaching that location. The greater the color change the more H2O2 that it is being exposed to.


Once you have developed your cycle then it is time to validate it. Validation of an iHP cycle requires some specialized equipment and resources but execution is straightforward.


Biological indicators (BIs) are the key component when validating your iHP cycle. Similar to how CIs are used in the development stage, BIs are used in the validation stage by being placed around the room in areas identified during development. BIs carry highly resistant bacteria, which are only inactivated when exposed to the required dose of iHP.


Following the completion of your validation cycle(s), the exposed BIs are collected, placed in growth media, and incubated at 60°C for 7 days. If no growth is observed after 7 days, then the biodecontamination cycle was successful and is now validated and ready for use.