Cleanroom & GMP Post-Construction Cleaning Service

If you need decontamination but do not have the resources, time or equipment, Vibraclean has your solution. From the smallest enclosure to a large building, our skilled personnel provide the customised treatment you require:

Ideal for:

  • Bio Safety–Level Labs 2, 3 and 4
  • Post-Construction New-Area Commissioning
  • Additional Research Areas
  • Pharmaceutical Production Areas
  • Annual Shutdown for Area Maintenance
  • Emergency Containment Control and Elimination

POST-CONSTRUCTION CLEANING

Building out a cleanroom and adjacent environments is a multi-stage construction process.

Vibraclean GMP cleaners meet the standards outlined in the Scope of Work and complete their work in the agreed time frame to avoid project delays. All Vibraclean GMP cleaners arrive outfitted with the correct Personal Protective Equipment (PPE).

After post construction cleaning, the room is ready is for pre-validation cleaning. This further reduces particles and residue levels to within desired operating parameters.

Post-construction cleaning Level 1

Level 1
Clean Construction

During Level 1, cleanliness begins to take on more importance.
To start, conduct daily and hourly cleanups using vacuums and start using a daily cleaning service. There should be no unnecessary trash or debris in the cleanroom area.
We recommend using multiple rugs as well as sticky mats to prevent dirt from entering.
This is also the post construction cleaning stage to conduct particle counts.

Post-construction cleaning Level 2

Level 2
Pre Cleanroom Construction

In Level 2, control and limit access to the cleanroom area.
First, establish a smock room/airlock for entry/exit with an air cleaner. Workers must wear booties in the area and use sticky mats on floors. In addition, no wood, cardboard or paper are allowed in the area.
A HEPA vacuum is required for cleanup after all cutting/drilling in the cleanroom.
Further, the air systems should be on, but not the filter fan units.

Post-construction cleaning Level 3

Level 3
Active Cleanroom Construction

Level 3 is for finishing details and is the most restrictive in post construction cleaning. It includes all the precautions of Level 2, plus several additional steps.
Workers must use a designated smock room and have limited access at this stage.
Before entering the cleanroom, workers must be fully smocked. This includes wearing lab coats or coveralls, hair/beard nets, booties and gloves and mask.
The recirculation air system should also be employed to continuously clean the air.

PRE VALIDATION CLEANING

Pre validation cleaning

Pass Certification The First Time

Not only do Vibraclean GMP cleaners meet the standards outlined in the Scope of Work, they complete their work in the agreed time frame to avoid project delays.

We follow your existing SOP or, in the case of a new facility, review your proposed cleaning plan and offer suggestions on how best to achieve the cleanliness target.

Pre-validation cleaning is a comprehensive multi-stage process.The process concentrates on all top, bottom, and vertical cleanroom surfaces. This includes ceilings, walls, floors, benches and fittings. We remove contaminants where necessary through disinfection.

Pre validation cleaning

In addition, Vibraclean GMP cleaners are thorough in their work. We review site-specific procedures, and work in a systematic way for pre-validation cleaning.

Our cleaners gown up appropriately with all necessary PPE equipment, too. We complete your compliance paperwork and oversee all our work to achieve the desired results

Pre validation cleaning

We have capability to supply trained cleanroom cleaners and equipment for periodic major cleans.

This can save you from sourcing and training extra labour, outfitting them with the proper cleaning gear, and supervising their performance.

Our pre-validation cleaning expertise enhances your ability to pass certification the first time.

FACILITY SHUT DOWN

POST-CONSTRUCTION CLEANING

Best Industry Practices to Ensure a Smooth Shutdown and a Rapid Startup.
Once a cleanroom is built, the HVAC system is operating and all equipment is installed, a meticulous initial clean is required prior to validation and use. This may require a facility shut down clean.

This important event is performed rapidly, under close control and within the cGMPS

PHASE ONE: Pre-shutdown activities (planning and scheduling).
PHASE TWO: Declassification and handover.
PHASE THREE: Day-to-day. management and handover.
PHASE FOUR: Reclassification and handover.
PHASE FIVE: Post-shutdown activities and completion of the shutdown report.

CLINICAL & MEDICAL LAB CLEANING

Clinical & Medical Lab Cleaning

Vibraclean specializes in routine lab facility cleaning and maintenance.
Not only do Vibraclean GMP cleaners meet the standards outlined in the Scope of Work, they complete their work in the agreed time frame to avoid project delays.

All Vibraclean GMP cleaners arrive outfitted with the correct Personal Protective Equipment (PPE) to conduct the pre-validation cleaning services. Vibraclean is capable and prepared to carry out effective clinical and medical lab cleaning in a variety of labs, including:

  • Compound Labs
  • Biosafety Labs
  • Incubator Labs
  • Production Labs
  • Analytical and Quality Labs
  • Research and Development (R&D) Labs
  • Clinical and Medical Labs (pathology, serology, histology, virology, bacteriology and molecular biology)

Trained and Reliable Team

First and foremost, all Vibraclean cleaners are trained to not disturb laboratory equipment and bench top items throughout the cleaning process. In addition, our cleaners pass Canadian Police criminal record checks.

Custom SOP

When it is time to discuss the level of lab cleaning needed, Vibraclean can follow your current Scope of Work and Standard Operating Procedures (SOPs) or we can help review and create new procedures for your medical lab. Most importantly, we work together to ensure your success and satisfaction.